Homepage > Digital servo controllers > AKD
Digital servo amplifiers AKD are designed for driving of rotary and
linear synchronous servomotors. Servo amplifiers are equipped
with multiple inputs for communication with many types of positioning
sensors. This gives us the possibility to find an optimum priced
solution of a used feedback sensor and of a servomotor application.
Digital servo amplifiers AKD are designed to be easily connected to different control systems, because of this the servo amplifiers can be used in many applications. In relation to the application and control system used, it is possible to utilize the integrated motion functions or to use only the basic functions of control loops.
Rated data | DIM | AKD-P00306 | AKD-P00606 | AKD-P01206 | AKD-P02406 | ||||
Rated supply voltage | V~ | 3x108–264 V / 50–60 Hz 1x108-264 V / 50–60 Hz |
3x240 V ± 10 % | ||||||
Rated installed power for S1 operation | kVA | 1.2 | 2.38 | 3.82 | 7.6 | ||||
Nominal current (±3 %) | |||||||||
– at rated voltage 120 V | Aef | 3 | 6 | 12 | – | ||||
– at rated voltage 240 V | Aef | 3 | 6 | 12 | 24 | ||||
Maximum current (max. 5s, ±3 %) | Aef | 9 | 18 | 30 | 48 | ||||
Continuous power regen circuit (RBint) | W | - | - | 100 | 200 | ||||
Continuous power regen circuit (RBext) max. | Ws | 60 (120 V) 20 (240 V) |
60 (120 V) 20 (240 V) |
160 (120 V) 55 (240 V) |
180 (120 V) 60 (240 V) |
||||
Continuous power regen circuit (RBext) max. | kW | 0.77 | 1.5 | 3 | 6 | ||||
Peak power regen circuit (RBext) max. | kW | 5.4 | 5.4 | 5.4 | 11.8 |
||||
Dimensions | |||||||||
- Height | mm | 168 | 168 | 195 | 250 | ||||
- Width | mm | 57 | 57 | 76 | 100 | ||||
- Depth | mm | 153 | 153 | 186 | 230 | ||||
- Depth with connectors | mm | 184 | 184 | 215 | 265 |
Rated data | DIM | AKD-P00307 | AKD-P00607 | AKD-P01207 | AKD-P02407 | AKD-P04807 |
Rated supply voltage | V~ | 3x216–528 V / 50–60 Hz | ||||
Rated installed power for S1 operation | kVA | 2.24 | 4.49 | 7.65 | 15.2 | 40.9 |
Nominal current (±3 %) | Aef | 3 | 6 | 12 | 24 | 48 |
Maximum current (max. 5s, ±3 %) | Aef | 9 | 18 | 30 | 48 | 96 |
Continuous power regen circuit (RBint) | W | 80 | 100 | 100 | 200 | - |
Breaking energy of regen circuit capacitor | Ws | 5 (240 V) 35 (400 V) 20 (480 V) |
5 (240 V) 35 (400 V) 20 (480 V) |
10 (240 V) 70 (400 V) 40 (480 V) |
15 (240 V) 110 (400 V) 60 (480 V) | 20 (240 V) 146 (400 V) 80 (480 V) |
Continuous power regen circuit (RBext) max. | ||||||
at 240 V / 400 V and 480 V | kW | 0.77 / 1.5 | 1.5 / 3 | 3 / 6 | 6 / 12 | 6 / 12 |
Peak power regen circuit (RBext) max. | kW | 5.4 / 21.4 | 5.4 / 21.4 | 5.4 / 21.4 | 7.7 / 30.6 | 17.6 / 70.5 |
Dimensions | ||||||
- Height | mm | 256 | 256 | 256 | 310 | 385 |
- Width | mm | 70 | 70 | 70 | 105 | 185 |
- Depth | mm | 186 | 186 | 186 | 229 | 229 |
- Depth with connectors | mm | 221 | 221 | 221 | 264 | 264 |